Networkd-Native VM Networking Design

Executive Summary

This document describes a networking architecture for Volt VMs that replaces virtio-net with networkd-native approaches, achieving significantly higher performance through kernel bypass and direct hardware access.

Performance Comparison

Backend Throughput Latency CPU Usage Complexity
virtio-net (user) ~1-2 Gbps ~50-100μs High Low
virtio-net (vhost) ~10 Gbps ~20-50μs Medium Low
macvtap ~20+ Gbps ~10-20μs Low Low
AF_XDP ~40+ Gbps ~5-10μs Very Low High
vhost-user-net ~25 Gbps ~15-25μs Low Medium

Architecture Overview

┌─────────────────────────────────────────────────────────────────────────┐
│                           Host Network Stack                             │
│  ┌─────────────────────────────────────────────────────────────────┐    │
│  │                    systemd-networkd                              │    │
│  │  ┌──────────────┐  ┌──────────────┐  ┌──────────────────────┐  │    │
│  │  │ .network     │  │ .netdev      │  │ .link                │  │    │
│  │  │ files        │  │ files        │  │ files                │  │    │
│  │  └──────────────┘  └──────────────┘  └──────────────────────┘  │    │
│  └─────────────────────────────────────────────────────────────────┘    │
│                                                                          │
│  ┌───────────────────────────────────────────────────────────────────┐  │
│  │                     Network Backends                               │  │
│  │                                                                     │  │
│  │  ┌─────────────┐  ┌─────────────┐  ┌─────────────┐               │  │
│  │  │  macvtap    │  │   AF_XDP    │  │ vhost-user  │               │  │
│  │  │  Backend    │  │  Backend    │  │  Backend    │               │  │
│  │  │             │  │             │  │             │               │  │
│  │  │ /dev/tapN   │  │ XSK socket  │  │ Unix sock   │               │  │
│  │  └──────┬──────┘  └──────┬──────┘  └──────┬──────┘               │  │
│  │         │                │                │                       │  │
│  │  ┌──────┴────────────────┴────────────────┴──────┐               │  │
│  │  │             Unified NetDevice API              │               │  │
│  │  │          (trait-based abstraction)             │               │  │
│  │  └────────────────────────┬───────────────────────┘               │  │
│  │                           │                                        │  │
│  └───────────────────────────┼────────────────────────────────────────┘  │
│                              │                                           │
│  ┌───────────────────────────┼───────────────────────────────────────┐  │
│  │                    Volt VMM                                   │  │
│  │                           │                                        │  │
│  │  ┌────────────────────────┴───────────────────────────────────┐  │  │
│  │  │                    VirtIO Compatibility                     │  │  │
│  │  │  ┌─────────────────┐  ┌─────────────────┐                  │  │  │
│  │  │  │ virtio-net HDR  │  │  Guest Driver   │                  │  │  │
│  │  │  │ translation     │  │  Compatibility  │                  │  │  │
│  │  │  └─────────────────┘  └─────────────────┘                  │  │  │
│  │  └────────────────────────────────────────────────────────────┘  │  │
│  └───────────────────────────────────────────────────────────────────┘  │
│                                                                          │
│                              ▼                                           │
│                    ┌─────────────────┐                                   │
│                    │   Physical NIC  │                                   │
│                    │  (or veth pair) │                                   │
│                    └─────────────────┘                                   │
└─────────────────────────────────────────────────────────────────────────┘

Why macvtap?

  • No bridge needed: Direct attachment to physical NIC
  • Near-native performance: Packets bypass userspace entirely
  • Networkd integration: First-class support via .netdev files
  • Simple setup: Works like a TAP but with hardware acceleration
  • Multi-queue support: Scale with multiple vCPUs

How it Works

┌────────────────────────────────────────────────────────────────┐
│                         Guest VM                                │
│  ┌──────────────────────────────────────────────────────────┐  │
│  │                   virtio-net driver                       │  │
│  └────────────────────────────┬─────────────────────────────┘  │
└───────────────────────────────┼─────────────────────────────────┘
                                │
┌───────────────────────────────┼─────────────────────────────────┐
│  Volt VMM                │                                  │
│  ┌────────────────────────────┴─────────────────────────────┐  │
│  │              MacvtapDevice                                │  │
│  │  ┌───────────────────────────────────────────────────┐   │  │
│  │  │  /dev/tap<ifindex>                                 │   │  │
│  │  │  - read() → RX packets                             │   │  │
│  │  │  - write() → TX packets                            │   │  │
│  │  │  - ioctl() → offload config                        │   │  │
│  │  └───────────────────────────────────────────────────┘   │  │
│  └──────────────────────────────────────────────────────────┘  │
└───────────────────────────────┬─────────────────────────────────┘
                                │
                    ┌───────────┴───────────┐
                    │   macvtap interface   │
                    │   (macvtap0)          │
                    └───────────┬───────────┘
                                │ direct attachment
                    ┌───────────┴───────────┐
                    │   Physical NIC        │
                    │   (eth0 / enp3s0)     │
                    └───────────────────────┘

macvtap Modes

Mode Description Use Case
vepa All traffic goes through external switch Hardware switch with VEPA
bridge VMs can communicate directly Multi-VM on same host
private VMs isolated from each other Tenant isolation
passthru Single VM owns the NIC Maximum performance

Option 2: AF_XDP (Ultra-High Performance)

Why AF_XDP?

  • Kernel bypass: Zero-copy to/from NIC
  • 40+ Gbps: Near line-rate on modern NICs
  • eBPF integration: Programmable packet processing
  • XDP program: Filter/redirect at driver level

How it Works

┌────────────────────────────────────────────────────────────────────┐
│                             Guest VM                                │
│  ┌──────────────────────────────────────────────────────────────┐  │
│  │                      virtio-net driver                        │  │
│  └────────────────────────────┬─────────────────────────────────┘  │
└───────────────────────────────┼─────────────────────────────────────┘
                                │
┌───────────────────────────────┼─────────────────────────────────────┐
│  Volt VMM                │                                      │
│  ┌────────────────────────────┴─────────────────────────────────┐  │
│  │                     AF_XDP Backend                            │  │
│  │  ┌────────────────────────────────────────────────────────┐  │  │
│  │  │                    XSK Socket                           │  │  │
│  │  │  ┌──────────────┐  ┌──────────────┐                    │  │  │
│  │  │  │  UMEM        │  │  Fill/Comp   │                    │  │  │
│  │  │  │  (shared mem)│  │  Rings       │                    │  │  │
│  │  │  └──────────────┘  └──────────────┘                    │  │  │
│  │  │  ┌──────────────┐  ┌──────────────┐                    │  │  │
│  │  │  │  RX Ring     │  │  TX Ring     │                    │  │  │
│  │  │  └──────────────┘  └──────────────┘                    │  │  │
│  │  └────────────────────────────────────────────────────────┘  │  │
│  └──────────────────────────────────────────────────────────────┘  │
└───────────────────────────────┬─────────────────────────────────────┘
                                │
                    ┌───────────┴───────────┐
                    │    XDP Program        │
                    │    (eBPF redirect)    │
                    └───────────┬───────────┘
                                │ zero-copy
                    ┌───────────┴───────────┐
                    │    Physical NIC       │
                    │    (XDP-capable)      │
                    └───────────────────────┘

AF_XDP Ring Structure

                UMEM (Shared Memory Region)
    ┌─────────────────────────────────────────────┐
    │ Frame 0 │ Frame 1 │ Frame 2 │ ... │ Frame N │
    └─────────────────────────────────────────────┘
         ↑                    ↑
         │                    │
    ┌────┴────┐          ┌────┴────┐
    │ RX Ring │          │ TX Ring │
    │ (NIC→VM)│          │ (VM→NIC)│
    └─────────┘          └─────────┘
         ↑                    ↑
         │                    │
    ┌────┴────┐          ┌────┴────┐
    │  Fill   │          │  Comp   │
    │  Ring   │          │  Ring   │
    │ (empty) │          │ (done)  │
    └─────────┘          └─────────┘

Option 3: Direct Namespace Networking (nspawn-style)

For containers and lightweight VMs, share the kernel network stack:

┌──────────────────────────────────────────────────────────────────┐
│  Host                                                             │
│  ┌────────────────────────────────────────────────────────────┐  │
│  │                   Network Namespace (vm-ns0)               │  │
│  │  ┌──────────────────┐                                      │  │
│  │  │  veth-vm0        │ ◄─── Guest sees this as eth0         │  │
│  │  │  10.0.0.2/24     │                                      │  │
│  │  └────────┬─────────┘                                      │  │
│  └───────────┼────────────────────────────────────────────────┘  │
│              │ veth pair                                          │
│  ┌───────────┼────────────────────────────────────────────────┐  │
│  │           │            Host Namespace                       │  │
│  │  ┌────────┴─────────┐                                      │  │
│  │  │  veth-host0      │                                      │  │
│  │  │  10.0.0.1/24     │                                      │  │
│  │  └────────┬─────────┘                                      │  │
│  │           │                                                 │  │
│  │  ┌────────┴─────────┐                                      │  │
│  │  │  nft/iptables    │  NAT / routing                       │  │
│  │  └────────┬─────────┘                                      │  │
│  │           │                                                 │  │
│  │  ┌────────┴─────────┐                                      │  │
│  │  │  eth0            │  Physical NIC                        │  │
│  │  └──────────────────┘                                      │  │
│  └────────────────────────────────────────────────────────────┘  │
└──────────────────────────────────────────────────────────────────┘

Voltainer Integration

Shared Networking Model

Volt VMs can participate in Voltainer's network zones:

┌─────────────────────────────────────────────────────────────────────┐
│                        Voltainer Network Zone                        │
│                                                                      │
│  ┌─────────────┐  ┌─────────────┐  ┌─────────────┐                 │
│  │ Container A │  │ Container B │  │  Volt  │                 │
│  │ (nspawn)    │  │ (nspawn)    │  │     VM      │                 │
│  │             │  │             │  │             │                 │
│  │  veth0      │  │  veth0      │  │  macvtap0   │                 │
│  │  10.0.1.2   │  │  10.0.1.3   │  │  10.0.1.4   │                 │
│  └──────┬──────┘  └──────┬──────┘  └──────┬──────┘                 │
│         │                │                │                         │
│  ┌──────┴────────────────┴────────────────┴──────┐                 │
│  │                  zone0 bridge                  │                 │
│  │                  10.0.1.1/24                   │                 │
│  └────────────────────────┬───────────────────────┘                 │
│                           │                                          │
│                    ┌──────┴──────┐                                  │
│                    │   nft NAT   │                                  │
│                    └──────┬──────┘                                  │
│                           │                                          │
│                    ┌──────┴──────┐                                  │
│                    │   eth0      │                                  │
│                    └─────────────┘                                  │
└─────────────────────────────────────────────────────────────────────┘

networkd Configuration Files

All networking is declarative via networkd drop-in files:

/etc/systemd/network/
├── 10-physical.link          # udev rules for NIC naming
├── 20-macvtap@.netdev        # Template for macvtap devices
├── 25-zone0.netdev           # Voltainer zone bridge
├── 25-zone0.network          # Zone bridge configuration
├── 30-vm-<uuid>.netdev       # Per-VM macvtap
└── 30-vm-<uuid>.network      # Per-VM network config

Implementation Phases

Phase 1: macvtap Backend (Immediate)

  • Implement MacvtapDevice replacing TapDevice
  • networkd integration via .netdev files
  • Multi-queue support

Phase 2: AF_XDP Backend (High Performance)

  • XSK socket implementation
  • eBPF XDP redirect program
  • UMEM management with guest memory

Phase 3: Voltainer Integration

  • Zone participation for VMs
  • Shared networking model
  • Service discovery

Selection Criteria

┌─────────────────────────────────────────────────────────────────┐
│                     Backend Selection Logic                      │
├─────────────────────────────────────────────────────────────────┤
│                                                                  │
│   Is NIC XDP-capable?  ──YES──►  Need >25 Gbps?  ──YES──►       │
│          │                              │                        │
│          NO                             NO                       │
│          ▼                              ▼                        │
│   Need VM-to-VM on host?         Use AF_XDP                     │
│          │                                                       │
│    ┌─────┴─────┐                                                │
│   YES         NO                                                 │
│    │           │                                                 │
│    ▼           ▼                                                 │
│  macvtap    macvtap                                             │
│  (bridge)   (passthru)                                          │
│                                                                  │
└─────────────────────────────────────────────────────────────────┘